Demonstration and Cost Analysis of a Building Retrofit Using High Performance Insulation

Descriptive Note:

Technical Report

Corporate Author:

U.S. Army Engineer Research and Development Center Champaign United States

Personal Author(s):

Report Date:

2013-05-18

Pagination or Media Count:

62.0

Abstract:

The Department of Energy DOE estimates that, in 2010, for all U.S. buildings including Department of Defense DOD Facilities,15.6 quads of primary energy consumption was attributable to fenestration and opaque building envelope components, of which the wall-related primary energy consumption was about 21 percent, or 3.3 quads. For commercial facilities, primary energy consumption attributed to walls during heating cycles was 1.48 quads, or is similar to 30 percent of total energy consumption due to building envelope components. Heat loss through walls during a heating cycle is a critical component of overall facility energy use and mitigation measures are important to reduce total facility energy consumption. This project demonstrated and validated the use of modified atmosphere insulation MAI to reduce wall-related energy consumption in DOD facilities. A combination of facility sensors and modeling activities were used to determine the effectiveness of the MAI. By retrofitting walls and increasing their thermal resistance R-value by R10-20 h-sq ft-degrees FBtu, reductions of 30 percent or more over the baseline wall-generated space conditioning loads are possible. This report analyzes the cost and performance aspects of the MAI technology.

Subject Categories:

  • Non-electrical Energy Conversion
  • Logistics, Military Facilities and Supplies

Distribution Statement:

APPROVED FOR PUBLIC RELEASE