Accession Number:

AD1039529

Title:

Gold Standard Testing of Motion Based Tracking Systems

Descriptive Note:

Technical Report,01 Jun 2016,31 Mar 2017

Corporate Author:

711th Human Performance Wing Wright-Patterson AFB United States

Personal Author(s):

Report Date:

2017-03-15

Pagination or Media Count:

19.0

Abstract:

Comparison testing and validation of the Zebra and Catapult tracking systems against a Gold Standard on-field measurement system for human physiological performance monitoring. Data shows that the accuracy of the Zebra RFID-based system is very good, due to its high sampling frequency, with most measurements being within 2 for distance and 4 for velocity as compared to our standard method. However, the GPS-based Catapult system exceeded 4 error for distance measurements.

Subject Categories:

  • Miscellaneous Detection and Detectors
  • Anatomy and Physiology

Distribution Statement:

APPROVED FOR PUBLIC RELEASE