Abstract:

This report presents the results of the reliability testing of the MIL-STD-781B type performed on the ANAAS-18 Infrared Detecting Set IRDS Cryogenic Cooler. This test was an essential part of the reconnaissance Increased Reliability of Operational Systems IROS Program. The reliability test was performed by the OOAMA Service Engineering Division at Hill AFB, Utah. Author

Subject Categories:

  • Air Conditioning, Heating, Lighting and Ventilating
  • Infrared Detection and Detectors

Distribution Statement: