Abstract:
Most modern spectral analysis systems time-share a single narrow-band filter and detector among a large number of frequency channels and thus provide sampled rather than continuous data to output averaging devices. For practical filter designs and finite sampling rates, a loss in performance is experienced due to this sampling. Analytical means are developed for computing this loss, and the loss is evaluated for a number of common filter shapes. Losses of 1 to 2 dB are shown to occur when th detector is sampled at rates comparable to the detector bandwidth. Author
Distribution Statement:
APPROVED FOR PUBLIC RELEASE