Accession Number:

AD0875745

Title:

Tensile Properties of HY 80 Steel Welds Containing Defects Correlated with Ultrasonic and Radiographic Evaluation.

Descriptive Note:

Final technical rept.,

Corporate Author:

NAVAL ORDNANCE LAB WHITE OAK MD

Personal Author(s):

Report Date:

1970-08-25

Pagination or Media Count:

35.0

Abstract:

Tensile testing was performed on HY 80 welds containing the specific defects slag, lack of fusion, and incomplete penetration. The tensile properties were correlated with ultrasonic and radiographic evaluation in terms of acceptance criteria of the Naval Ship Systems Command. The results of this work indicate a high degree of confidence for static application for welds evaluated by this criteria. Author

Subject Categories:

  • Couplers, Fasteners and Joints
  • Marine Engineering

Distribution Statement:

APPROVED FOR PUBLIC RELEASE