DID YOU KNOW? DTIC has over 3.5 million final reports on DoD funded research, development, test, and evaluation activities available to our registered users. Click
HERE to register or log in.
Accession Number:
AD0856896
Title:
RCS Propellant Tank Thermostat Test.
Descriptive Note:
Final rept.
Corporate Author:
MCDONNELL CO ST LOUIS MO
Report Date:
1968-05-23
Pagination or Media Count:
16.0
Abstract:
The propellant and oxidizer tanks of the Gemini B Reentry Control System incorporate thermostatically controlled heaters to maintain their temperature within prescribed limits. Tests were performed to develop a method to verify operation of the thermostats while the tanks are installed in the spacecraft. The tests showed that the thermostats can be cooled to actuation temperature in four minutes or less using cold nitrogen gas or a mixture of Freon 12 and nitrogen. Author
Distribution Statement:
APPROVED FOR PUBLIC RELEASE