Vibration Test of 58T030051-1 Gemini B Adapter Relay Panel Assembly.
Descriptive Note:
Final rept.,
Corporate Author:
MCDONNELL CO ST LOUIS MO
Report Date:
1967-03-30
Pagination or Media Count:
198.0
Abstract:
Vibration testing was conducted on a 58T030051-1 Relay Panel Assembly to determine if the assembly was electrically and structurally capable of withstanding the vibration environment specified in Test Request 058-AVB.04. The vibration-test program was conducted in six phases. Phases 1 and 2 consisted of determining the accelerations in the transverse axes of the exciter systems, without and with the hard-mounted relay panel. Phases 3 and 4 were a frequency-response test and a random-vibration test with the relay panel shock mounted. Phases 5 and 6 were a frequency-response test and a random-vibration test with the relay panel hard mounted. Author