Accession Number:

AD0856655

Title:

Massive Overload of Kynar (5M974 and 5M975) Insulated Wire in Air.

Descriptive Note:

Final rept.,

Corporate Author:

MCDONNELL CO ST LOUIS MO

Personal Author(s):

Report Date:

1967-11-30

Pagination or Media Count:

22.0

Abstract:

Results are presented for a test conducted to evaluate the electrical overload characteristics of wire bundles fabricated from polyvinylidene outer space wire. The two test specimens were subjected to massive overload tests in ambient air. Each test specimen was also subjected to a preliminary dielectric strength test at 1500 Vrms. Author

Subject Categories:

  • Electrical and Electronic Equipment
  • Safety Engineering
  • Manned Spacecraft

Distribution Statement:

APPROVED FOR PUBLIC RELEASE