Abstract:

This report defines tests performed to determine the characteristic change in current and voltage as the liquid probe is covered or uncovered by liquid oxygen, to determine the characteristic change in current and voltage for the liquid level probes as the ullage pressure is varied, and to determine the effect on probe voltage when the pressurizing media is changed from helium to nitrogen. Author

Subject Categories:

  • Electrical and Electronic Equipment
  • Surface-Launched Guided Missiles
  • Liquid Rocket Propellants

Distribution Statement: