Accession Number:
AD0843935
Title:
Dynamic Testing of Shock Cord.
Descriptive Note:
Rept. for 18 Sep-20 Oct 67,
Corporate Author:
AIR FORCE SPECIAL WEAPONS CENTER KIRTLAND AFB NM
Report Date:
1968-04-01
Pagination or Media Count:
28.0
Abstract:
Static and dynamic load characteristics were obtained for both new and fatigued 34-inch diameter shock cord at 50, 75, and 100 percent elongation. These tests were conducted to calibrate shock cord displacement gages installed for the HEST V experiment. It was determined that the shock cord would fail when elongated beyond 105 percent and that the cord would be in a fatigued condition with minimal creep when subjected to 100 percent elongation for 12 days. It was also determined that the load transmitted by the shock cord when subjected to a shock pulse was related to the relative motion of the ends of the cord. Author
Distribution Statement:
APPROVED FOR PUBLIC RELEASE