Abstract:

The purpose of the test is to evaluate ball valves for possible use in the silo loading system and to acquire data which can be used as life test data, should one of the test specimens later be selected for pre-production testing. Author

Subject Categories:

  • Pumps, Filters, Pipes, Tubing, Fittings and Valves
  • Guided Missile Launching and Basing Support

Distribution Statement:

APPROVED FOR PUBLIC RELEASE