Accession Number:

AD0783638

Title:

CIRIS Transponder Deployments for Testing Inertial Navigation Systems.

Descriptive Note:

Final technical rept.,

Corporate Author:

INTERMETRICS INC CAMBRIDGE MA

Personal Author(s):

Report Date:

1974-08-13

Pagination or Media Count:

217.0

Abstract:

The completely integrated reference instrumentation system CIRIS system at Holloman Air Force Base provides a highly precise reference for the flight testing of navigation and guidance systems. CIRIS subsystems include an inertial navigation system INS, a Doppler velocity sensor, and a precision ranging system. This report evaluates the effect of the deployment of the transponders of the precision ranging system on CIRIS positionvelocityattitude accuracy and on the estimation of sources of error in an INS under test. Position accuracy with basic two and three transponder deployments is explored with a simple position fix error analysis. Positionvelocityattitude accuracy for a variety of multi-transponder deployments is evaluated using the CIRIS post-flight processor on simulated CIRIS flight data. The performance improvement with Doppler data is presented. Modified author abstract

Subject Categories:

  • Navigation and Guidance

Distribution Statement:

APPROVED FOR PUBLIC RELEASE