Abstract:

The paper discusses an analysis of processes occurring during operation of iron-nickel batteries. In the range of above-zero temperatures C, the capacity of batteries in the starter discharge mode is limited by the positive electrode, not the negative electrode. The battery charging voltage of 75 v 1.63 velement currently used causes extreme overcharging of batteries and excessive heating. This significantly reduces the service life of batteries and decreases their operating reliability.

Subject Categories:

  • Electrochemical Energy Storage

Distribution Statement:

APPROVED FOR PUBLIC RELEASE