Accession Number:

AD0779859

Title:

An Electronic Integrator for Transient Shock Signatures.

Descriptive Note:

Technical rept.,

Corporate Author:

NAVAL ORDNANCE LAB WHITE OAK MD

Personal Author(s):

Report Date:

1974-03-14

Pagination or Media Count:

19.0

Abstract:

The report describes an electronic integrator developed for use in obtaining velocity-time signatures from transient shock signatures. The integrator consists of three assemblies an integrator circuit, a square wave calibrator, and a triggered relay control circuit. Both real time and magnetically taped data can be accommodated. The output is scaled to convert the input in units of acceleration in g to provide an output in units of velocity in feet per second. A brief background discussion and typical operational procedures are presented. Author

Subject Categories:

  • Test Facilities, Equipment and Methods

Distribution Statement:

APPROVED FOR PUBLIC RELEASE