Accession Number:

AD0779250

Title:

Influence of Calibration Procedure Upon Determination of J sub I sub c for a Titanium 6Al-4V Alloy.

Descriptive Note:

Final rept.,

Corporate Author:

NAVAL RESEARCH LAB WASHINGTON D C

Personal Author(s):

Report Date:

1974-04-30

Pagination or Media Count:

27.0

Abstract:

The influence of calibration procedure on the determination of J sub I sub c from fatigue-precracked elastic-plastic specimens of a Ti-6Al-4V alloy has been examined. Results are compared from five compliance-type calibrations, each derived from sets of load vs load-point-displacement diagrams which differ in origin. These sets include diagrams obtained from notched specimens of two different thicknesses, diagrams generated analytically from the plane-stress and plane-strain solutions of Bucci et al. as corrected for machine contribution to displacement, and from the uncorrected plane-stress solution which simulates well the load vs load-point-displacement behavior of the fatigue-precracked specimens. The J sub I sub c results obtained from these five calibrations are in substantial agreement with each other and with a known value of K sub I sub c for this material. Preliminary results from application of the deep-slot bend approximation are in accord with those determined from the compliance-type calibration procedures. Autho

Subject Categories:

  • Metallurgy and Metallography

Distribution Statement:

APPROVED FOR PUBLIC RELEASE