DID YOU KNOW? DTIC has over 3.5 million final reports on DoD funded research, development, test, and evaluation activities available to our registered users. Click
HERE to register or log in.
Accession Number:
AD0777805
Title:
Correlation between Breathing Zone Solvent Concentrations and Solvent Zones from Vapor Degreasers.
Descriptive Note:
Final comprehensive rept. Jun-Dec 73,
Corporate Author:
DELAWARE UNIV NEWARK DEPT OF CIVIL ENGINEERING
Report Date:
1974-04-01
Pagination or Media Count:
113.0
Abstract:
The study found that, under laboratory conditions, the concentrations of solvent vapors in the air can be predicted mathematically with good accuracy. Extending the use of the model to industrial operations, it was shown that the emissions from an actual vapor degreaser can also be estimated. The model can therefore, be applied to optimize ventilation design, optimize degreaser design to achieve maximum efficiency with minimum emissions and optimize existing degreaser operating procedures. The results of the field sampling performed in conjunction with this study revealed a definite requirement to have a cover installed on all vapor degreasers. Such an installation will not only protect the worker at or near the degreaser, it will significantly reduce solvent usage. Modified author abstract
Distribution Statement:
APPROVED FOR PUBLIC RELEASE