Accession Number:

AD0777673

Title:

Inspection History of Chicago Bridge and Iron Co. Steam Receivers used on TC13 Mod 0 and Mod 1 Steam Catapults.

Descriptive Note:

Interim rept. Oct 65-Nov 73,

Corporate Author:

NAVAL AIR TEST FACILITY LAKEHURST N J

Personal Author(s):

Report Date:

1974-04-08

Pagination or Media Count:

17.0

Abstract:

The report describes the various inspections performed on three steam receivers. The various methods used to inspect the receivers were visual, magnetic particle, ultrasonic, radiographic, and dye penetrant. The steam receivers were used at the TC13 and TC13 Mod 1 catapult sites from October 1965 to November 1973. This is the first time in five inspections that any cracks were found. All previous inspections found the receivers free of defects. The cracks found during this inspection in no way affect the structural strength of the receivers. All cracks were ground out and fairedblended into surrounding metal. No repair welding was needed. Inspection of all three receivers will be conducted every 18 months to insure structural integrity of the receivers. Author

Subject Categories:

  • Terminal Flight Facilities
  • Hydraulic and Pneumatic Equipment
  • Test Facilities, Equipment and Methods

Distribution Statement:

APPROVED FOR PUBLIC RELEASE