DID YOU KNOW? DTIC has over 3.5 million final reports on DoD funded research, development, test, and evaluation activities available to our registered users. Click
HERE to register or log in.
Accession Number:
AD0777303
Title:
Stress Analysis and Stability of Oil Storage Tank Floating Roofs,
Descriptive Note:
Corporate Author:
NAVAL CONSTRUCTION RESEARCH ESTABLISHMENT DUNFERMLINE (SCOTLAND)
Report Date:
1972-11-01
Pagination or Media Count:
19.0
Abstract:
The report shows how the complex behavior of the more common type of floating roof may be resolved into discrete problem areas. The analysis assumes static loading, and, on this basis, examines the probability of various collapse mechanisms. Restorative buoyancy effects were established as the primary stabilizing factor when considering overall buckling of the pontoon ring. Author
Distribution Statement:
APPROVED FOR PUBLIC RELEASE