Accession Number:

AD0765342

Title:

Carbon Dioxide Monitoring.

Descriptive Note:

Final technical rept., 1 Mar-14 Jul 73,

Corporate Author:

ROCKWELL INTERNATIONAL CORP ANAHEIM CALIF ELECTRONICS RESEARCH DIV

Report Date:

1973-08-14

Pagination or Media Count:

91.0

Abstract:

The program was initiated to establish the feasibility of applying bioluminescent technology for monitoring of carbon dioxide CO2 in life-support systems for divers, swimmers and underwater habitats. Experiments were performed to obtain bioluminescent cultures which are sensitive to levels of carbon dioxide as low as 81 ppm, in an 80 helium and 20 oxygen life-support gas mixture--at hydrostatic pressures up to 1000 psig. Fourteen luminescent cultures were tested under conditions of varying pressures, gas proportions, sample sizes, and flow rates. Strong responses to low concentrations of CO2 were exhibited by five cultures--thereby demonstrating the feasibility of employing a luminescent detection system in the environments of interest. The luminescent responses were sensed by a photomultiplier tube. The photomultiplier output was fed through a log amplifier to a strip-chart recorder. This detection system was more than adequate for laboratory measurements however, the requirements for a more compact system were also examined. It appears that--by using a solid-state sensor and integrated-circuit electronics--a small, low-power, portable unit can be developed and constructed. This unit would provide fail-safe monitoring of CO2 in underwater life-support systems. Author

Subject Categories:

  • Life Support Systems

Distribution Statement:

APPROVED FOR PUBLIC RELEASE