DID YOU KNOW? DTIC has over 3.5 million final reports on DoD funded research, development, test, and evaluation activities available to our registered users. Click
HERE to register or log in.
Accession Number:
AD0760396
Title:
Nonstationary Heat and Mass Exchange in the Area,
Descriptive Note:
Corporate Author:
ARMY FOREIGN SCIENCE AND TECHNOLOGY CENTER CHARLOTTESVILLE VA
Report Date:
1973-03-07
Pagination or Media Count:
12.0
Abstract:
The study of non-steady-state heat or mass transfer in the region of the forward stagnation point has great significance. As the results of experimental investigation of transverse flow around a cylinder show, the flow pattern in the rear zone -- namely in the neighborhood of the rear stagnation point over a certain range of Re -- is analogous to the flow in the region of the forward stagnation point. The author considers a round cylinder surrounded by a steady liquid flow field. Heat and mass transfer to the cylinder are described by equations. Two cases are of interest 1 concentration or temperature at the surface of the cylinder varies according to some arbitrary function 2 concentration or temperature change occurs discontinuously.
Distribution Statement:
APPROVED FOR PUBLIC RELEASE