DID YOU KNOW? DTIC has over 3.5 million final reports on DoD funded research, development, test, and evaluation activities available to our registered users. Click
HERE to register or log in.
Accession Number:
AD0754900
Title:
Heat Production for Air Force Fog Dissipation Program.
Descriptive Note:
Final rept. 15 Apr 71-27 Oct 72,
Corporate Author:
ULTRASYSTEMS INC IRVINE CALIF
Report Date:
1972-10-27
Pagination or Media Count:
56.0
Abstract:
A heating system was supplied and operated to support an AFCRL test program of warm fog dispersal. The system consisted of four parallel rows of liquid propane burners and associated tanks, pumps, and fuel lines. The maximum heat release was 600 million Btuhr which was adequate to clear fog along a 400-ft width, 200 ft high in 10 mph winds of 40 degrees range in direction. A total of 191 tests were run 63 with fog and 128 with clear air. This report describes the system and presents a log of the heating rates and burner arrangements which were operated for the tests conducted by AFCRL. Author
Distribution Statement:
APPROVED FOR PUBLIC RELEASE