Accession Number:

AD0751023

Title:

Systems Analysis of Vidicon Optics for the Electronic Periscope View Simulator.

Descriptive Note:

Technical rept.,

Corporate Author:

NAVAL TRAINING DEVICE CENTER ORLANDO FLA

Personal Author(s):

Report Date:

1972-02-01

Pagination or Media Count:

31.0

Abstract:

New, high resolution vidicon tubes are being developed for T. V. applications. The resolution requirements of one such tube are reviewed and the specialized optical probe required for an electronic periscope view simulator is analyzed. Conventional optical analysis, with the exception of pupil magnification, is used to show that desired system resolution can be attained if model scale is flexible. The graphical results indicate that an 8001 scale aircraft carrier is usable if 25 resolution degradation over 40 of the length of the model is acceptable for the closest simulated range. If stricter resolution and depth of field requirements are desired than larger models must be used. Author

Subject Categories:

  • Test Facilities, Equipment and Methods
  • Optical Detection and Detectors
  • Non-Radio Communications

Distribution Statement:

APPROVED FOR PUBLIC RELEASE