Accession Number:

AD0749543

Title:

Bleachable Absorber Laser Amplifier and Defector (BALAD)

Descriptive Note:

Semi-annual rept., 18 Nov 1970 - 17 Nov 1971

Corporate Author:

POLYTECHNIC INST OF BROOKLYN FARMINGDALE NY

Personal Author(s):

Report Date:

1972-04-14

Pagination or Media Count:

41.0

Abstract:

A detailed feasibility and design study has been made on the wide- angle, low noise BALAD receiver Bleachable Absorber Laser Amplifier and Detector. Expressions have been derived for the achievable field-of-view, maximum gain and other specifications in terms of the dimensions and the measurable properties of the laser and absorber gases. Virtually error free detection is assured for signal pulses 100 photons. A figure-of-merit has been measured for several absorber gases screened from the literature. BALAD receivers with 4000 resolution element field-of-view are feasible using SF6 with a CO2 amplifier at 10.0 micrometer and Xe with Xe at 3.5 micrometer. The use of the latter is recommended for the experimental test of the BALAD receiver. Two compact absorber configurations have been considered and will be further investigated. Application is to optical radar and to optical communications where signal direction is uncertain.

Subject Categories:

  • Infrared Detection and Detectors
  • Non-Radio Communications

Distribution Statement:

APPROVED FOR PUBLIC RELEASE