DID YOU KNOW? DTIC has over 3.5 million final reports on DoD funded research, development, test, and evaluation activities available to our registered users. Click
HERE to register or log in.
Accession Number:
AD0744096
Title:
Plasma Display Terminal.
Descriptive Note:
Final rept. 18 May-18 Dec 71,
Corporate Author:
OWENS-ILLINOIS INC TOLEDO OHIO ADMINISTRATIVE DIV
Report Date:
1972-05-01
Pagination or Media Count:
124.0
Abstract:
The report contains the results of a study and test program to determine the feasibility of using an Owens-Illinois, Inc. DIGIVUE model 51260 sixty element per linear inch plasma displaymemory device in military airborne environments. The study used MIL-E-5400L, Class 1A as a baseline. Five panels were tested to the following MIL-STD-810B environments Altitude Method 500, Procedure 1 High Temperature Method 501, Procedure II, 2 cycles only Low Temperature Method 502 Temperature Shock Method 503, Step 1-5, 8-10 Temperature-Humidity-Altitude Method 518 Modified, one cycle only and limited to the following thermal conditions Operating -25C to 55C, Non-Operating -62C to 85C.
Distribution Statement:
APPROVED FOR PUBLIC RELEASE