DID YOU KNOW? DTIC has over 3.5 million final reports on DoD funded research, development, test, and evaluation activities available to our registered users. Click
HERE to register or log in.
Accession Number:
AD0744058
Title:
Performance Evaluation of Three Subsonic Annular Diffusers,
Descriptive Note:
Corporate Author:
SYSTEMS RESEARCH LABS INC DAYTON OHIO
Report Date:
1972-04-01
Pagination or Media Count:
36.0
Abstract:
An experimental investigation of the performance of three subsonic annular diffusers has been made. These diffusers have the same axial length 18-34 in. and the same outlet-to-inlet area ratio 2.76 and the same outlet-to-inlet area ratio 2.76 and were tested at inlet velocities from approximately 100-450 feet per second. The basis on which their comparative performance was evaluated is static pressure recovery. The straight wall diffuser with a divergence angle of 12 degrees was found to be the best of the three available diffusers. The measured static pressure recovery coefficient of .6 is not particularly good, though conditions discussed in the report suggest in actual use the performance would be somewhat better. Author
Distribution Statement:
APPROVED FOR PUBLIC RELEASE