Accession Number:

AD0738793

Title:

Fluerics 30. The Matched Acoustic Generator

Descriptive Note:

[Technical Report, Technical Report]

Corporate Author:

HARRY DIAMOND LABS ADELPHI MD

Report Date:

1971-12-01

Pagination or Media Count:

21

Abstract:

A swept-frequency, matched acoustic generator for quickly measuring the insertion power gain and bandwidth of flueric components was developed and tested. The generator produces and measures the signal incident on flueric elements unaffected by their reflections. The components are connected to the generator by transmission lines. The output of the flueric unit is measured in a line of the same diameter as the input line and long enough to attenuate reflections from the far end of the line to negligible levels.

Descriptors:

Subject Categories:

  • Fluidics and Fluerics

Distribution Statement:

[A, Approved For Public Release]