Accession Number:

AD0738629

Title:

Hazard Study of Six Helium-Neon Laser Boresights.

Descriptive Note:

Final rept.,

Corporate Author:

SCHOOL OF AEROSPACE MEDICINE BROOKS AFB TEX

Personal Author(s):

Report Date:

1972-02-01

Pagination or Media Count:

13.0

Abstract:

Six helium-neon laser boresights at US Air Force bases in the continental United States were surveyed to determine their output power. The study indicated the measured output power of these devices to be significantly below their rated output power of 1.3 mw. The measured output power ranged from 0.97 to 0.14 mw. The laser boresights surveyed do not constitute eye hazards as defined in AFM 161-8 C1, 27 September 1971. Author

Subject Categories:

  • Radiobiology
  • Fire Control and Bombing Systems

Distribution Statement:

APPROVED FOR PUBLIC RELEASE