Accession Number:

AD0735843

Title:

Stilling Basin, Huntington Reservoir Spillway, Wabash River, Indiana: Hydraulic Model Investigation,

Descriptive Note:

Corporate Author:

ARMY ENGINEER WATERWAYS EXPERIMENT STATION VICKSBURG MISS

Personal Author(s):

Report Date:

1967-02-01

Pagination or Media Count:

26.0

Abstract:

Tests were conducted on a 160-scale section model of the Huntington Reservoir spillway to assist in development of the most economic energy dissipator which would provide reasonably good dissipation at low and intermediate flows and safe conditions at a flow of 98,000 cfs 80 percent of the spillway design flood. A 130-ft-long horizontal apron with one row of baffle piers and an end sill met the above requirements and was recommended for use in the prototype.

Subject Categories:

  • Civil Engineering

Distribution Statement:

APPROVED FOR PUBLIC RELEASE