Accession Number:

AD0733473

Title:

On the Optimum Step Response of Bandlimited Systems,

Descriptive Note:

Corporate Author:

CALIFORNIA UNIV LOS ANGELES DEPT OF MATHEMATICS

Personal Author(s):

Report Date:

1971-11-18

Pagination or Media Count:

19.0

Abstract:

The following bounds for the overshootundershoot epsilon of the unit step response of a bandlimited system are derived 1pi the integral from omega0T to infinity of K sub 0 XidXiepsilon1piK sub 0omega sub 0T, where 2T is the rise time, -omega sub 0, omega sub0 the bandwidth and K sub 0 the zeroth order modified Bessel function of the second kind. The suboptimal response corresponding to the upper bound is also discussed. Author

Subject Categories:

  • Electrical and Electronic Equipment
  • Operations Research

Distribution Statement:

APPROVED FOR PUBLIC RELEASE