Accession Number:

AD0706705

Title:

CALIBRATION OF THE NOL LARGE SCALE GAP TEST WITH A PENTOLITE DONOR II

Descriptive Note:

Corporate Author:

NAVAL ORDNANCE LAB WHITE OAK MD

Personal Author(s):

Report Date:

1970-03-17

Pagination or Media Count:

17.0

Abstract:

Henceforth the standard donor in the NOL large scale gap test will be 5050 pentolite pellets pressed to a density of 1.56 gcc instead of the tetryl pellets previously used. The pentolite donors will be supplied by NAD, Crane, Indiana. This report gives the current calibration curve for the large scale gap test with the pentolite donors.

Subject Categories:

  • Test Facilities, Equipment and Methods
  • Ammunition and Explosives
  • Armor

Distribution Statement:

APPROVED FOR PUBLIC RELEASE