Accession Number:

AD0702042

Title:

THE CALIBRATION CORRELATION FUNCTION FOR POSITIVE DISPLACEMENT LIQUID METERS.

Descriptive Note:

Research and development rept.,

Corporate Author:

NAVAL SHIP ENGINEERING CENTER PHILADELPHIA PA PHILADELPHIA DIV

Personal Author(s):

Report Date:

1969-12-16

Pagination or Media Count:

132.0

Abstract:

The report presents a correlation function for precessing disc positive displacement oil meters. This correlation will predict the shift in the calibration curve due to differences in fluid conditions with an accuracy of plus or minus 12. The prerequisite is a recent and valid calibration of that meter under known fluid conditions. The analysis and approach presented in this report are applicable to all designs of positive displacement flow meters. Author

Subject Categories:

  • Marine Engineering
  • Test Facilities, Equipment and Methods

Distribution Statement:

APPROVED FOR PUBLIC RELEASE