DID YOU KNOW? DTIC has over 3.5 million final reports on DoD funded research, development, test, and evaluation activities available to our registered users. Click
HERE to register or log in.
Accession Number:
AD0653011
Title:
CYCLOTRON WAVE DEVICES STUDY.
Descriptive Note:
Quarterly rept. no. 8,
Corporate Author:
UTAH UNIV SALT LAKE CITY MICROWAVE DEVICE AND PHYSICAL ELECTRONICS LAB
Report Date:
1966-12-01
Pagination or Media Count:
39.0
Abstract:
An analysis of force-free mode coupling in the Cuccia coupler is carried out to supplement the transverse mode coupling analysis. The complete analytical and experimental results on the cyclotron-synchronous wave amplifier are available in AD-653 009. A computer analysis of the power converter was carried out which includes space-charge and finite beam size effects. These calculations give results not too different than the filamentary beam results. Using the same space-charge beam model as that used in the power converter analysis, a beam stability computer calculation was carried out for the amplifier. The results are somewhat different than the published curves of Sackinger and Buck, and Bass. Author
Distribution Statement:
APPROVED FOR PUBLIC RELEASE