Abstract:

This evaluation was conducted in support of an elevated temperature fatigue test program. The measurement of strain at temperatures up to 600F using a 450F rated bakelite backed, constantan foil strain gage is described. This gage was found to be usable up to this temperature.

Subject Categories:

  • Test Facilities, Equipment and Methods

Distribution Statement:

APPROVED FOR PUBLIC RELEASE