DID YOU KNOW? DTIC has over 3.5 million final reports on DoD funded research, development, test, and evaluation activities available to our registered users. Click
HERE to register or log in.
Accession Number:
AD0648669
Title:
TORSIONAL VIBRATION STUDY OF 250 KW D.C. DIESEL GENERATOR SET FOR INSTALLATION ON DOLPHIN (AGSS 555).
Descriptive Note:
Final rept.,
Corporate Author:
DAVID TAYLOR MODEL BASIN WASHINGTON D C ACOUSTICS AND VIBRATION LAB
Report Date:
1967-01-01
Pagination or Media Count:
24.0
Abstract:
A torsional vibration test was carried out on a 250 KW D.C. Diesel Generator set to be installed on DOLPHIN AGSS 555. Test results show that the levels of torsional stresses at various resonances are well below the maximum limits as determined by MIL-STD-167. Author
Distribution Statement:
APPROVED FOR PUBLIC RELEASE