Abstract:

Preliminary tests were made using the specified 11 mg Mylar particles with velocities of 40,000 to 60,000 ftsec and 2024 aluminum bumpers and targets. The results indicate that a 532-inch bumper is required to stop the particle. A detailed description of the hypervelocity facility is given. Author