Abstract:

An electronic calibration circuit for use in applying five linear deflections of either charge or voltage to a cathode-ray tube recording system is described. The use of Western Electric mercury contact relays and the method of operating them from sequential one-shot multivibraters is explained. Included are photographs of the various types of calibration deflections obtainable with the circuit, and complete drawings of the circuit and associated power supply. Author

Subject Categories:

  • Electrical and Electronic Equipment
  • Test Facilities, Equipment and Methods

Distribution Statement: