Accession Number:

AD0633233

Title:

EXPERIMENTAL PROTOTYPE PACKAGE VENTILATION KIT, FIRST STRUCTURAL AND HUMAN FACTORS TEST

Descriptive Note:

Interim rept., 29 Mar-12 Apr 1965

Corporate Author:

GENERAL AMERICAN TRANSPORTATION CORP NILES IL GENERAL AMERICAN RESEARCH DIV

Personal Author(s):

Report Date:

1965-05-01

Pagination or Media Count:

71.0

Abstract:

A structural test and human limit evaluation of the shelter Package Ventilation Kit PVK showed that the ventilator can be readily operated for periods of at least three hours with 7-12 minutes rest each half-hour. The PVK can be operated at pedal speeds from 45 to 63 RPM, and the preferred speed was 55 RPM. The optimum power input was found to be 0.10 horsepower per operator, and the maximum tested was 0.15. Most tests were performed at comfortable conditions, 68 to 72 F effective temperature ET. The maximum ET imposed was 83 F. Further tests are required to establish workrest cycles when operating the PVK at elevated ETs.

Subject Categories:

  • Air Conditioning, Heating, Lighting and Ventilating
  • Structural Engineering and Building Technology
  • Human Factors Engineering and Man Machine Systems

Distribution Statement:

APPROVED FOR PUBLIC RELEASE