MILLIMETER AND SUBMILLIMETER DEVICE RESEARCH.
Descriptive Note:
Quarterly progress rept. no. 1, 1 Jul-1 Oct 65,
Corporate Author:
MARTIN CO ORLANDO FLA
Report Date:
1965-10-01
Pagination or Media Count:
23.0
Abstract:
Molecular beam investigations were continued with the Ramsey interferometers separated by 27 inches. This operation yields a linewidth as narrow as 350 cps. Broadening effects continue to be present. A description is given of a molecular beam apparatus which is being prepared for observations on lithium fluoride. Various experimental aspects of the molecular beam work and of millimeter techniques are discussed. Author
Distribution Statement:
APPROVED FOR PUBLIC RELEASE