Accession Number:

AD0618676

Title:

APPLICATION OF AN ANTICOINCIDENCE-SHIELDED SCINTILLATION SPECTROMETER TO THE STUDY OF THE N14(P,GAMMA)015 REACTION.

Descriptive Note:

Technical rept.,

Corporate Author:

NAVAL ORDNANCE LAB WHITE OAK MD

Personal Author(s):

Report Date:

1965-05-11

Pagination or Media Count:

82.0

Abstract:

A gamma-ray spectrometer was built using a liquidscintillator anticoincidence shield for a 5 in dia x 10 in long NaIT1 crystal. The spectrometer was used to study radiation from the N14p, gamma015 reaction for proton energies of from 0.97 to 1.96 MeV. Decay schemes for the 8.29, 8.75, 8.92, and 8.98 Mev levels in 015 were derived. Author

Subject Categories:

Distribution Statement:

APPROVED FOR PUBLIC RELEASE