Accession Number:

AD0615979

Title:

WATER RECLAMATION FROM URINE THERMOELECTRIC SYSTEM

Descriptive Note:

Technical Report,01 May 1963,31 Oct 1964

Corporate Author:

WHIRLPOOL CORP ST JOSEPH MI ST JOSEPH United States

Personal Author(s):

Report Date:

1965-03-01

Pagination or Media Count:

26.0

Abstract:

The project was inititated to design, fabricate, and test a thermoelectric system for the recovery of potable water from urine in aerospace applications. The unit built is an integral system, which yields quality potable water at a performance factor of 146 watt-hours per pound. It has a capacity of processing 12 liters of urine per day with a batch size of 1 liter per run. Further development work should be undertaken toward obtaining better efficiencies, a decrease in size, and a reduction in weight.

Subject Categories:

Distribution Statement:

APPROVED FOR PUBLIC RELEASE