Accession Number:

AD0611425

Title:

OPERATION OF THE NOLC X-BAND RADIOMETER,

Descriptive Note:

Corporate Author:

NAVAL ORDNANCE LAB CORONA CALIF

Personal Author(s):

Report Date:

1964-12-01

Pagination or Media Count:

49.0

Abstract:

This report describes the NOLC X-band mapping radiometer. All phases of the operation are discussed, and the methods used for calibration of the radiometer calibrate-temperature step are explained. An analysis of the system losses is presented, and the effect of these losses on the radiometer measurements is described. Author

Subject Categories:

Distribution Statement:

APPROVED FOR PUBLIC RELEASE