DID YOU KNOW? DTIC has over 3.5 million final reports on DoD funded research, development, test, and evaluation activities available to our registered users. Click
HERE to register or log in.
Accession Number:
AD0610469
Title:
FILTER CRYSTAL TEST SET AND STANDARD CRYSTAL MEASUREMENT SYSTEM.
Descriptive Note:
Final rept. for Jul 62-Aug 64,
Corporate Author:
SYSTEMS INC ORLANDO FLA
Report Date:
1964-08-01
Pagination or Media Count:
122.0
Abstract:
The development of two equipments to be used for the measurement of quartz crystal parameters is presented. The characteristics of the Filter Crystal Test Set include a frequency range of 0.8 to 100 mc. and the capability for measurements of the main mode, unwanted modes, and static capacitance. The characteristics of the Standard Crystal Measurement System include a frequency range of 0.8 to 200 mc. and the capability for highly accurate bridgetype measurements of all crystal parameters utilizing the servo-bridge technique Army Electronics Research and Development Agency, Fort Monmouth, N. J. A new method to simplify bridge type measurements on quartz crystal units, by E. Hafner, 8 Nov 1957. Rept E-1220, PB-163 812. In addition, this report discusses the overall crystal measurement problem and the relation of the equipments developed under this contract to this overall problem. The uses and limitations of the equipment as well as the relations between the two types of equipment are discussed.
Distribution Statement:
APPROVED FOR PUBLIC RELEASE