Accession Number:

AD0609395

Title:

PRODUCTION ENGINEERING OF TRIAXIAL PULSE CONNECTORS.

Descriptive Note:

Consolidated rept. for 16 Dec 62-30 Sep 64,

Corporate Author:

BURNDY CORP NORWALK CONN

Personal Author(s):

Report Date:

1964-09-30

Pagination or Media Count:

36.0

Abstract:

Engineering Samples of the UG1292U and UG1291U Connector assemblies were tested and evaluated. Certain modifications to the design are necessary to assure proper termination of the first shield, to assure proper elimination of air voids at the mating surfaces. Engineering Samples of the UG1296U, P-230 and P-190 connector assemblies were tested and evaluated. Corona characteristics after temperature cycling indicated a degree of degradation of the cable has taken place. This was quite apparent relative to the RG230U cable. Author

Subject Categories:

Distribution Statement:

APPROVED FOR PUBLIC RELEASE