DID YOU KNOW? DTIC has over 3.5 million final reports on DoD funded research, development, test, and evaluation activities available to our registered users. Click
HERE to register or log in.
Accession Number:
AD0607175
Title:
LIMITING SYNCHRO LOADS IN 400 CYCLE CONTROL, TORQUE AND MIXED SYSTEMS FOR MIL-S-20708A SYNCHROS.
Descriptive Note:
Final rept. p. 1,
Corporate Author:
NAVAL APPLIED SCIENCE LAB BROOKLYN N Y
Report Date:
1964-01-01
Pagination or Media Count:
39.0
Abstract:
Limiting synchro loads in 400 cycle systems, load current for 3 percent voltage regulation and optimum capacities have been determined for synchros fabricated under military specification MIL-S-20708A. Limiting loads have been determined from measured synchro parameters, applied to formulae developed by the Laboratory. Synchro loads that may be carried in control, torque and mixed control-torque systems are tabulated in the report. Load currents and optimum values for synchro capacitors, two of the parameters used to determine synchro loads, are also tabulated. Author
Distribution Statement:
APPROVED FOR PUBLIC RELEASE