Accession Number:

AD0485896

Title:

THERMIONIC CONVERTER LIFE AND REPEATABILITY INVESTIGATION.

Descriptive Note:

Quarterly progress rept. no. 9, 1 Apr-30 Jun 66,

Corporate Author:

THERMO ELECTRON CORP WALTHAM MA

Personal Author(s):

Report Date:

1966-06-30

Pagination or Media Count:

75.0

Abstract:

This report covers the work accomplished on thermionic converters, generators, and thermionic converter additives. Efforts during this quarter included emitter and collector work function measurements of five converters which are on life-test. No appreciable change in either the emitter or the collector work function has been found with time of operation. Metallurgical and chemical analysis has been performed on one converter 403-series that failed after 993 cycles of operation. Five converters are being life-tested on a steady-state basis and all five have surpassed the contract goal of 5000 hours of continuous operation. Two converters of the 402-series have passed 13200 and 12100 hours of operation respectively, and at the end of the reporting period, had identical power density outputs of 16.6 Wsq cm. Three converters of the 403-series have passed 6200, 5300 and 5000 hours of operation respectively, with corresponding power density outputs of 17.3, 17.8 and 16.5 Wsq cm. One converter of the 404-series was acceptance-tested. All converters operate at an output voltage of 0.7 volt and an emitter temperature of 2000 K.

Subject Categories:

  • Electric Power Production and Distribution

Distribution Statement:

APPROVED FOR PUBLIC RELEASE