Accession Number:

AD0485370

Title:

INVESTIGATION FOR 2000 F POWER WIRE.

Descriptive Note:

Quarterly rept. no. 4, 22 Mar-21 Jun 66,

Corporate Author:

MELPAR FALLS CHURCH VA

Personal Author(s):

Report Date:

1966-06-21

Pagination or Media Count:

25.0

Abstract:

This report discusses the last two methods evaluated for coating rhodium wire with flexible high temperature dielectric films. Thermal decomposition of triple-oxide coating and electrostatic deposition have been successfully completed. The final design of the power wire consists in bulk insulation of Kaowool, Refrasil sleeving, and quartz cord the outer sheath is a knitted inconel wire mesh with monel electrical terminals. Power wire evaluation testing was completed and fabrication of sample wires has been initiated. Author

Subject Categories:

  • Coatings, Colorants and Finishes

Distribution Statement:

APPROVED FOR PUBLIC RELEASE