Accession Number:

AD0460450

Title:

DETERMINATION OF RESPONSES OF PROTECTED AND UNPROTECTED ELECTRIC INITIATORS TO ELECTRICAL STIMULI.

Descriptive Note:

Special technical rept.,

Corporate Author:

GENISTRON INC COLLEGE PARK MD APPLIED RESEARCH DIV

Personal Author(s):

Report Date:

1965-02-26

Pagination or Media Count:

85.0

Abstract:

The effectiveness against electromagnetic fields of ten samples of Metavac ferrite-ceramic RF attenuators, intended for application as in-line protective devices for electroexplosive initiators, was measured. The measurements were performed over the frequency range from 100 cps through 10 gc. Quantities directly measured were input impedance, load impedance of the connected inert MK-1 squib, transfer impedance, or Degree of Protection. These data were used to compute the evaluation parameters Power Attenuation, Corrected Power Attenuation, and minimum possible Insertion Loss, which are presented in graphic form. The time delay of all samples was found to be less than the 0.2 microsecond resolution available in the instrumentation. Author

Subject Categories:

Distribution Statement:

APPROVED FOR PUBLIC RELEASE