Accession Number:

AD0457075

Title:

THE NITROUS OXIDE DOSIMETER--INFLUENCE OF CELL DIAMETER ON THE NITROGEN YIELD,

Descriptive Note:

Corporate Author:

NAVAL RADIOLOGICAL DEFENSE LAB SAN FRANCISCO CA

Personal Author(s):

Report Date:

1965-01-05

Pagination or Media Count:

8.0

Abstract:

The effect of cell diameter on the nitrogen yield from Co6O gamma-irradiated gaseous nitrous oxide has been examined. The Fricke dosimeter was used as the reference of absorbed dose. The dose actually absorbed by the gas was calculated by the Bragg-Gray principle. The results obtained indicate there is no significant dependence on GN2 on cell diameter. The mean GN2 of 11.4 or - 0.8 obtained here compared well with values reported by other workers. Author

Subject Categories:

Distribution Statement:

APPROVED FOR PUBLIC RELEASE