DID YOU KNOW? DTIC has over 3.5 million final reports on DoD funded research, development, test, and evaluation activities available to our registered users. Click
HERE to register or log in.
Accession Number:
AD0435969
Title:
THE DEVELOPMENT OF A STAB-INITIATED, HERMETICALLY SEALED DELAY DETONATOR (DETONATOR WOX-58A),
Descriptive Note:
Corporate Author:
NAVAL ORDNANCE LAB WHITE OAK MD
Report Date:
1961-06-30
Pagination or Media Count:
20.0
Abstract:
A stab-initiated, hermetically-sealed, delay detonator has been developed for use in the Depth Charge WOX-3A. This detonator has an overall length of 2.303 in. and a diameter of 0.500 in. It has a nominal delay, at room temperature, of 5.3 seconds with a standard deviation less than 0.09 second. It operates reliably over the temperature range -65 F to 160 F with an average delay time variation changing from 5.7 to 5.0 seconds. Its design is such that the delay composition. It produces an average mils with a standard deviation less than 0.39 mils. It passes the environmental tests MIL-STD-300, MIL-STD-301, MIL-STD-304, MIL-STD-305, MIL-STD353, and TN 1441-Via. It fails to pass environmental tests MIL-STD-302 forty-foot drop but, since there is an interruption system between this detonator and the main charge, this does not rule out use of the detonator in the Depth Charge WOX-3A. Author
Distribution Statement:
APPROVED FOR PUBLIC RELEASE