Accession Number:

AD0419651

Title:

REPEATER, TELEGRAPH TH-38 ()/G.

Descriptive Note:

Quarterly progress rept. no. 5, 1 Apr-30 June 63.

Corporate Author:

RADIATION INC MELBOURNE FLA

Personal Author(s):

Report Date:

1963-06-01

Pagination or Media Count:

27.0

Abstract:

The last Quarterly Report indicated that the first models built failed to pass vibration re quirements per SCL-4067. Further testing in this quarter indicated that the shock mounting provi sions were not adequate and that the unit did not meet MIL-I-11748 RFI requirements. The unit was completely redesigned, therefore, to insure com pliance with the requirements of SCL-4067. Two units were fabricated in this period. The rede signed units passed shock and vibration tests but, will require some additional effort on the next quarter to fully meet MIL-I-11748 RFI requirements. Author

Descriptors:

Subject Categories:

Distribution Statement:

APPROVED FOR PUBLIC RELEASE