Accession Number:
AD0419651
Title:
REPEATER, TELEGRAPH TH-38 ()/G.
Descriptive Note:
Quarterly progress rept. no. 5, 1 Apr-30 June 63.
Corporate Author:
RADIATION INC MELBOURNE FLA
Personal Author(s):
Report Date:
1963-06-01
Pagination or Media Count:
27.0
Abstract:
The last Quarterly Report indicated that the first models built failed to pass vibration re quirements per SCL-4067. Further testing in this quarter indicated that the shock mounting provi sions were not adequate and that the unit did not meet MIL-I-11748 RFI requirements. The unit was completely redesigned, therefore, to insure com pliance with the requirements of SCL-4067. Two units were fabricated in this period. The rede signed units passed shock and vibration tests but, will require some additional effort on the next quarter to fully meet MIL-I-11748 RFI requirements. Author